Well, first of all, execute the calibrate command on all available cell storage.
We are doing testing on Exadata Database Machine X3-2 1/8th
rack. Same procedure can be followed on any configuration of Exadata.
Cell Server 1
CellCLI> calibrate force
Calibration will take a few minutes...
Aggregate random read throughput across all hard disk LUNs: 1521 MBPS
Aggregate random read throughput across all flash disk LUNs: 8048.46 MBPS
Aggregate random read IOs per second (IOPS) across all hard disk LUNs: 2380
Aggregate random read IOs per second (IOPS) across all flash disk LUNs:
113116
Calibrating hard disks (read only) ...
LUN 0_0 on drive [20:0 ] random read throughput: 127.78 MBPS, and
200 IOPS
LUN 0_1 on drive [20:1 ] random read throughput: 125.87 MBPS, and
199 IOPS
………...
LUN 0_8 on drive [20:8 ] random read throughput: 128.98 MBPS, and
202 IOPS
LUN 0_9 on drive [20:9 ] random read throughput: 125.46 MBPS, and
200 IOPS
Calibrating flash disks (read only, note that writes will be significantly
slower) ...
LUN 1_0 on drive [FLASH_1_0] random
read throughput: 544.25 MBPS, and 36275 IOPS
LUN 1_1 on drive [FLASH_1_1] random
read throughput: 543.82 MBPS, and 36080 IOPS
LUN 5_2 on drive [FLASH_5_2] random
read throughput: 541.41 MBPS, and 36141 IOPS
…………..
LUN 5_3 on drive [FLASH_5_3] random
read throughput: 502.17 MBPS, and 36036 IOPS
CALIBRATE results are within an acceptable range.
Calibration has finished.
Cell Server 2
CellCLI> calibrate force
Calibration will take a few minutes...
Aggregate random read throughput across all hard disk LUNs: 1473 MBPS
Aggregate random read throughput across all flash disk LUNs: 7064.97 MBPS
Aggregate random read IOs per second (IOPS) across all hard disk LUNs: 2385
Aggregate random read IOs per second (IOPS) across all flash disk LUNs:
88501
Controller read throughput: 2008.34 MBPS
Calibrating hard disks (read only) ...
LUN 0_0 on drive [20:0 ] random read throughput: 130.67 MBPS, and
195 IOPS
LUN 0_1 on drive [20:1 ] random read throughput: 128.76 MBPS, and
195 IOPS
…………...
LUN 0_9 on drive [20:9 ] random read throughput: 134.11 MBPS, and
202 IOPS
Calibrating flash disks (read only, note that writes will be significantly
slower) ...
LUN 1_0 on drive [FLASH_1_0] random
read throughput: 539.54 MBPS, and 35125 IOPS
LUN 1_1 on drive [FLASH_1_1] random
read throughput: 538.50 MBPS, and 34983 IOPS
………………….
LUN 5_3 on drive [FLASH_5_3] random
read throughput: 536.68 MBPS, and 36299 IOPS
CALIBRATE results are within an acceptable range.
Calibration has finished.
Cell Server 3
CellCLI> calibrate force
Calibration will take a few minutes...
Aggregate random read throughput across all hard disk LUNs: 1492 MBPS
Aggregate random read throughput across all flash disk LUNs: 7082.99 MBPS
Aggregate random read IOs per second (IOPS) across all hard disk LUNs: 2379
Aggregate random read IOs per second (IOPS) across all flash disk LUNs:
106158
Controller read throughput: 1999.22 MBPS
Calibrating hard disks (read only) ...
LUN 0_0 on drive [20:0 ] random read throughput: 127.56 MBPS, and
190 IOPS
LUN 0_1 on drive [20:1 ] random read throughput: 128.84 MBPS, and
189 IOPS
…………….
LUN 0_9 on drive [20:9 ] random read throughput: 124.79 MBPS, and
201 IOPS
Calibrating flash disks (read only, note that writes will be significantly
slower) ...
LUN 1_0 on drive [FLASH_1_0] random
read throughput: 541.09 MBPS, and 35552 IOPS
LUN 1_1 on drive [FLASH_1_1] random
read throughput: 541.02 MBPS, and 35405 IOPS
……….
LUN 5_3 on drive [FLASH_5_3] random
read throughput: 544.38 MBPS, and 47843 IOPS
CALIBRATE results are within an acceptable range.
Calibration has finished.
Now let’s collect aggregate IOPS for Hard disk as well as for Flash disk from all the storage servers as per above output.
Cell-1
Aggregate random read IOs per second (IOPS) across all hard disk LUNs: 2380
Aggregate random read IOs per second (IOPS) across all flash disk LUNs:
113116
Cell-2
Aggregate random read IOs per second (IOPS) across all hard disk LUNs: 2385
Aggregate random read IOs per second (IOPS) across all flash disk LUNs:
88501
Cell-3
Aggregate random read IOs per second (IOPS) across all hard disk LUNs: 2379
Aggregate random read IOs per second (IOPS) across all flash disk LUNs:
106158
Final Calculation
Above result is showing IOPS for each cell storage. Now calculating IOPS
for entire Exadata rack by adding all the numbers for hard disk and flash disk.
Storage Cell Hard Disk IOPS 2380+2385+2379 = 7144 IOPS
Storage Cell Flash Hard Disk 113116+88501+106158 = 307775
IOPS
You can follow our Exadata Certification Question Bank to achieve maximum success in your Exadata certification.
You can follow our Exadata Certification Question Bank to achieve maximum success in your Exadata certification.
No comments: